4 digits display
Easy to use with front panel keypad
5A/60 mV, CT20/30 current transformer/60mV or 1A input
Programmable scale between 5A and 9999A
Multifunctional alarm output for upper and lower limits (order option)
Communication feature via isolated RS485, using ModBus RTU protocol (order option)
Measuring type can be selected as AC, DC or true RMS
0/4-20mA, 0-10V or 1-5V output selection (Only “A” type output devices)
Key lock feature
CT20/30 current transformer (order separately)
CE marked according to European Norms
Environmental Conditions | |
Ambient/Storage Temperature | 0 ...50 ºC / -25...70 ºC |
Relative Humidity | 80% Relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C |
Protection Degree | According to EN 60529 IP20 |
Height | Max. 2000m |
Electrical Characteristics | |
Supply | 90-250V AC 50/60Hz or 10-30V DC / 8-24V AC 50/60Hz |
Power consumption | 7VA |
External Connections | Screw-terminals |
Scale | AC and RMS: Input type 5A/60mV: 0...9999A (specified by c.tr.r parameter) For example: If c.tr.r=5, scale is 0...5A Input type CT20/30 or 60mV: If itYP=Ct20, input range is 0...300A (specified by turn parameter) For example: If turn=1, scale is 0...300A itYP=Ct30, input range is 0...120A (specified by tUrn parameter) For example: If turn=1, scale is 0...120A Input type 1A: 0...9999A (specified by c.tr.r parameter) For example: If c.tr.r=1, scale is 0...1A DC: Input type 5A/60mV: -999...9999A (specified by c.t.r.r parameter) For example: If c.tr.r=5, scale is -5...5A Input type CT20/30/60mV : DC Measurement can not be performed by using current transformer If itYP=SHnt, input range is -999..9999A (specified by c.tr.r parameter) For example: If c.tr.r=5, scale is -5...5A Input type 1A : -999...9999A (specified by c.t.r.r parameter) For example: c.tr.r=1 için scale -1...1A |
Sensitivity | 0.002A x c.t.r.r (for example, 0.01A for c.t.r.r=5) |
Accuracy | AC: ±1%(of full scale) (±2% for square wave form) DC: ±1% (of full scale) RMS: ±1% (of full scale) (±2% for square wave form) |
Input Range | Input type 60mV: -60mV...60mV (device may be damaged at 50V and above voltages) Input type 1A: -1A...1A (device may be damaged at 2A and above currents) Input type 5A: -5A...5A (device may be damaged at 10A and above currents) Input type CT20/30 : 0...150mA |
Input Impedance | Input type 60mV: 20kohm Input type 1A: 90mohm Input type 5A: 12mohm Input type CT20/30: 600mohm |
Frequency Range | DC, 20Hz - 70Hz |
Outputs | |
Alarm Output | Relay: 250V AC, 8A (for resistive load), NO+NC |
Analog Output | 0-20mA DC, 4-20mA DC, 0-10V DC or 1-5V DC selection (load resistance for current outputs are max. 500ohm) |
Life Expectancy | Mechanical 30.000.000 operations (under no load), Electrical 100.000 operations (8A at 250V AC, resistive load) |
Housing | |
Mounting Method | Panel mounting |
Dimensions | W77xH35xD61 mm |
Weight | Approx. 250g (after packaging) |
Enclosure Material | Self extinguishing plastics |