EDT3411
EDT3411 ENDA Product
  • Single NTC prob input

  • Additional offset feature for input

  • Defrosting duration and interval time settings

  • Delay time and minimum operating time settings for compressor protection

  • Compressor or door alarm control via digital input

  • Upper, lower and delay time settings for alarm

  • In case of probe failure, output status can be set to On, Off or periodic

  • Upper and Lower set point value limits can be adjusted

  • Temperature unit can be selected as °C or °F

  • CE marked according to European Norms

Manuals

Downloads

Environmental Conditions
Ambient/Storage Temperature 0...50 ºC / -25...70 ºC
Relative Humidity 80% relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C
Protection Degree According to EN 60529 Front panel:IP62, Rear panel:IP20
Height Max. 2000m
Electrical Characteristics
Supply 230V AC +%10 -%20 50/60Hz or 10-30V DC / 8-24V AC
Power Consumption 3VA
External Connections Screw-terminals
Scale -60.0...150.0 °C
Sensitivity 0.1 °C (Can be chosen as 0.1 ºC or 1 ºC)
Accuracy ±1 (of full scale) ±1 digit
Time accuracy ±1% - 1s
Output
Relay 8A model: NO+NC 250V AC, 8A (for resistive load)
20A model: NO 250V AC, 20A (for resistive load)

Life Expectancy 8A model: Mechanical 30.000.000 operations (under no load), Electrical 300.000 operations (8A at 250V AC, resistive load)
20A model: Mechanical 30.000.000 operations (under no load), Electrical 100.000 operations (20A at 250V AC, resistive load)

Control
Control type Single set-point
Control algorithm On-Off
Hysteresis Adjustable between 0.1 and 15.0 °C/F
Housing
Mounting Method Panel mounting
Dimensions W77xH35xD61 mm
Weight Approx. 215g (After packing)
Enclosure Material Self extinguishing plastics
Please choose your preferred language.
Switch to English