On-Off control
Two relay output can be selected for cooling and agitating
Single NTC prob input
Compressor protection parameters can be set
In case of probe failure, input status can be set to On, off or periodic
Upper and lower set point limits can be adjusted
Agitation ON and OFF duration can be adjusted
Lower and upper alarm limit can be adjusted to depending on set value
°F or °C temperature unit selection
External alarm function can be configured to digital inputs
Transfer device parameter settings with ENDA key no power-up required (order option)
RS485 ModBus protocol communication feature (order option)
CE marked according to European Norms
Environmental Conditions | |
Ambient/Storage Temperature | 0...50 ºC / -25...70 ºC |
Relative Humidity | 80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C |
Protection Degree | According to EN 60529 Front panel: IP65, Rear panel: IP20 |
Height | Max. 2000m |
Electrical Characteristics | |
Supply | 230V AC +%10 -%20 50/60Hz or 10-30V DC / 8-24V AC |
Power Consumption | 5VA |
External Connections | Screw-terminals |
Scale | -60.0...150.0 °C |
Sensitivity | 0.1 °C (selectable 0.1 ºC or 1 ºC) |
Accuracy | ±1 °C |
Time Accuracy | ±1% |
Output | |
Compressor Output | Relay: 277V AC, 20A (for resistive load), NO, 2hp, 1.49kW 250V AC (inductive load) |
Agitating Output | Relay: 250V AC, 8A (for resistive load), NO+NC, 1/2hp, 0.37kW 240V AC (inductive load) |
Life Expectancy | Compressor Relay: Mechanical 10.000.000 operations (under no load), Electrical 100.000 operations (20A at 277V AC, resistive load) Agitating Relay: Mechanical 30.000.000 operations (under no load), Electrical 100.000 operations (8A at 250V AC, resistive load) |
Control | |
Control Type | Single set-point |
Control Algorithm | On-Off |
Hysteresis | Adjustable between 1...20.0 °C |
Housing | |
Mounting Method | Panel mounting |
Dimensions | W77xH35xD61 mm |
Weight | Approx. 190g (after packaging) |
Enclosure Material | Self extinguishing plastics |