EPA942
  • 4 digits display

  • Easy to use with front panel keypad

  • Can be used with current transformer or shunt

  • Programmable scale between 5A and 9999A

  • Multifunctional alarm output for upper and lower limits (order option)

  • Communication feature via RS485 ModBus protocol (order option)

  • Measuring type can be selected as AC, DC or true RMS

  • Key lock feature

  • CE marked according to European Norms

Manuals

Environmental Conditions
Ambient/Storage Temperature0 ...50 ºC / -25...70 ºC
Relative Humidity80% Relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection DegreeAccording to EN 60529 Front panel: IP65, Rear panel: IP20
HeightMax. 2000m
Electrical Characteristics
Supply90-250V AC 50/60Hz or 10-30V DC / 8-24V AC 50/60Hz
Power Consumption7VA
External ConnectionsPlug-in terminals
ScaleAC and RMS: 0...9999A (specified by c.t.r.r parameter
For example: Scale is 0...5A for c.t.r.r=5.00)
DC: -999...9999A (specified by c.t.r.r parameter
For example: Scale is -5...5A for c.t.r.r=5.00)
Sensitivity0.001A x c.t.r.r/5 (for example, 0.001A for c.t.r.r=5)
AccuracyAC: ±1%(of full scale) (±2% for square wave form)
DC: ±1% (of full scale)
RMS: ±1% (of full scale) (±2% for square wave form)
Input Range-5...5A (device may be damaged at 10A and above currents)
-60...60mV (device may be damaged at 50V and above voltages)
Input ImpedanceCurrent transformer: 12mohm
Shunt: 40kohm
Frequency RangeDC, 10Hz - 200Hz (10Hz-70Hz For square wave form)
Outputs
Alarm Output2 Relays: 250V AC, 10A (for resistive load), NO+NC
Life ExpectancyMechanical 30.000.000 operations (under no load), Electrical 100.000 operations (8A at 250V AC, resistive load)
Housing
Mounting MethodPanel mounting
DimensionsW96xH96xD50 mm
WeightApprox. 410g (after packaging)
Enclosure MaterialSelf extinguishing plastics
Please choose your preferred language.