ATP4

48x48 mm, External Start-Reset-Gate Input, 2 Relay Outputs, Pin Socket or Terminal, Functional Timer

Compare
ATP4 Enda Product
Compare
  • Triggered by supply voltage

  • Triggering output (OUT1)

  • Contact output for timing function (OUT2)

  • 6 different timing modes for OUT2 (A, B, C, D, E, F)

  • 6 different timing unit for OUT2 (S, 10S, M, 10M, H, 10H)

  • 8/11 pin octal connector or 7/10 screw-terminal connection

  • Start, reset and gate inputs for 10 pins screw-terminal or 11 pin octal connector

  • CE marked according to European Norms

Manuals

Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529 Front panel: IP50, Rear panel: IP20
Height
Max. 2000m
Inputs
Start Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Reset Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Gate Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Control
Timing Function
A, B, C, D, E, F modes can be selected
Timing Unit
second, 10 seconds, minute, 10 minutes, hours and 10 hours on device
Electrical Characteristics
Supply
90-250V AC, 50/60Hz or 24V AC ±10%, 50/60Hz or 24V DC ±10%
Power Consumption
Max. 10VA
External Connections
8/11 pin octal connector or 7/10 pins plug-in terminals
Scale
0-1.2, 0-3, 0-12, 0-30 or 0-60
Reset Time
0.3s for ATP4-UV, 0.01s for ATP4-LV
Accuracy
Max. 0.2% fault depending on supply voltage
Max. 5% fault when setting set value
Max. 1% fault depending on temperature effect

Outputs
Trigger output OUT1
Relay: 250V AC, 8A (resistive load), NC
Control output OUT2
Relay: 250V AC, 8A (resistive load), NO+NC
Life Expectancy
Mechanical 30.000.000 operations (under no load), Electrical 100.000 operations (8A at 250V AC, resistive load)
Control Output State
OUT LED lit when control output is energized and flashes during timer operates
Housing
Mounting Method
Panel mounting or rail mounting with 8/11 pin octal connector
Dimensions
W48xH48xD82 mm
Weight
Approx. 100g (after packaging)
Enclosure Material
Self extinguishing plastics
Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529 Front panel: IP50, Rear panel: IP20
Height
Max. 2000m
Electrical Characteristics
Supply
90-250V AC, 50/60Hz or 24V AC ±10%, 50/60Hz or 24V DC ±10%
Power Consumption
Max. 10VA
External Connections
8/11 pin octal connector or 7/10 pins plug-in terminals
Scale
0-1.2, 0-3, 0-12, 0-30 or 0-60
Reset Time
0.3s for ATP4-UV, 0.01s for ATP4-LV
Accuracy
Max. 0.2% fault depending on supply voltage
Max. 5% fault when setting set value
Max. 1% fault depending on temperature effect

Inputs
Start Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Reset Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Gate Input
Switch inputs for 10 screw-terminal or 11 pin octal connector models (Pulsing time min. 3ms)
Outputs
Trigger output OUT1
Relay: 250V AC, 8A (resistive load), NC
Control output OUT2
Relay: 250V AC, 8A (resistive load), NO+NC
Life Expectancy
Mechanical 30.000.000 operations (under no load), Electrical 100.000 operations (8A at 250V AC, resistive load)
Control Output State
OUT LED lit when control output is energized and flashes during timer operates
Control
Timing Function
A, B, C, D, E, F modes can be selected
Timing Unit
second, 10 seconds, minute, 10 minutes, hours and 10 hours on device
Housing
Mounting Method
Panel mounting or rail mounting with 8/11 pin octal connector
Dimensions
W48xH48xD82 mm
Weight
Approx. 100g (after packaging)
Enclosure Material
Self extinguishing plastics