ATF02

18x90 mm, Rail Mounted, Flashing, Analog Timer

Compare
ATF02 Enda Product
Compare
  • Triggered by supply voltage

  • Triggering output (OUT1 order option)

  • Contact output for timing function (OUT2)

  • ton and toff time durations can be adjusted separately

  • 6 different timing units (S, 10S, M, 10M, H, 10H)

  • Rail mounting

  • Screw-terminal connection

  • CE marked according to European Norms

Manuals

Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529, IP20
Height
Max. 2000m
Outputs
Control Outputs OUT1/OUT2
2 Relays: 250V AC, 10A (for resistive load), NO+NC
Life Expectancy
Mechanical 10.000.000 operations (under no load), Electrical 50.000 operations (10A at 250V AC, resistive load)
Control Output State
OUT2 LED lit during ton time and flashes during toff time
Housing
Mounting Method
TH35 rail mounting
Dimensions
W18xH90xD66 mm
Weight
Approx. 90g (after packaging)
Enclosure Material
Self extinguishing plastics
Electrical Characteristics
Supply
90-250V AC 50/60Hz or 24V AC ±10%, 50/60Hz or 24V DC ±10%
Power Consumption
Max. 10VA
External Connections
Screw-terminals
Scale
Adjustable between 0 and 1
Reset Time
Max. 0.04s
Accuracy
Max. 0.2% fault depending on supply voltage
Max. 4.5% fault when setting set value
Max. 1% fault depending on temperature effect

Control
Timing Function
ton: ON time duration for relay, toff: OFF time duration for relay can be adjusted on device
Timing Unit
ON and OFF time durations can be selected as, second, 10 seconds, minute, 10 minutes, hours and 10 hours on device
Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529, IP20
Height
Max. 2000m
Electrical Characteristics
Supply
90-250V AC 50/60Hz or 24V AC ±10%, 50/60Hz or 24V DC ±10%
Power Consumption
Max. 10VA
External Connections
Screw-terminals
Scale
Adjustable between 0 and 1
Reset Time
Max. 0.04s
Accuracy
Max. 0.2% fault depending on supply voltage
Max. 4.5% fault when setting set value
Max. 1% fault depending on temperature effect

Outputs
Control Outputs OUT1/OUT2
2 Relays: 250V AC, 10A (for resistive load), NO+NC
Life Expectancy
Mechanical 10.000.000 operations (under no load), Electrical 50.000 operations (10A at 250V AC, resistive load)
Control Output State
OUT2 LED lit during ton time and flashes during toff time
Control
Timing Function
ton: ON time duration for relay, toff: OFF time duration for relay can be adjusted on device
Timing Unit
ON and OFF time durations can be selected as, second, 10 seconds, minute, 10 minutes, hours and 10 hours on device
Housing
Mounting Method
TH35 rail mounting
Dimensions
W18xH90xD66 mm
Weight
Approx. 90g (after packaging)
Enclosure Material
Self extinguishing plastics
Please choose your preferred language.