ET2413 - Temperature Controllers - Automation - Enda
ET2413

77x35 mm, NTC Input, 3 Relay Outputs, Vehicle Climate Control Unit

Compare
ET2413 Enda Product
Compare
  • Vehicle-mounted climate control device

  • 77 x 35 mm dimensions

  • 4-digit digital display

  • Decimal point display feature

  • Three contact outputs for fan and climate control

  • Fan and climate control is done manually via front panel keys

  • CE marked according to European Norms

Manuals

Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529 Front panel: IP65, Rear panel: IP20
Height
Max. 2000m
Output
FAN1
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
FAN2
Relay: 250V AC, 8A (for resistive load), NO+NC; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
A/C (Climate)
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
Life Expectancy
Mechanical 30.000.000 operations (under no load); Electrical 100.000 operations (8A at 250V AC, resistive load)
Electrical Characteristics
Supply
230V AC +10% -20% 50/60Hz, 10-30V DC / 8-24V AC SMPS
Power Consumption
Max. 5VA
External Connections
2.5mm² screw-terminals
Scale
-60.0...150.0 °C
Sensitivity
± 0.1°C
Accuracy
± 1°C
EMC
EN 61326-1:2013
Safety Requirements
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Housing
Mounting Method
Panel mounting
Dimensions
W77xH35xD61 mm
Weight
Approx. 190g (after packaging)
Enclosure Material
Self extinguishing plastics
Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree
According to EN 60529 Front panel: IP65, Rear panel: IP20
Height
Max. 2000m
Electrical Characteristics
Supply
230V AC +10% -20% 50/60Hz, 10-30V DC / 8-24V AC SMPS
Power Consumption
Max. 5VA
External Connections
2.5mm² screw-terminals
Scale
-60.0...150.0 °C
Sensitivity
± 0.1°C
Accuracy
± 1°C
EMC
EN 61326-1:2013
Safety Requirements
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Output
FAN1
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
FAN2
Relay: 250V AC, 8A (for resistive load), NO+NC; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
A/C (Climate)
Relay: 250V AC, 8A (for resistive load), NO; 1/2 HP 240V AC CosΦ = 0.4 (for inductive load)
Life Expectancy
Mechanical 30.000.000 operations (under no load); Electrical 100.000 operations (8A at 250V AC, resistive load)
Housing
Mounting Method
Panel mounting
Dimensions
W77xH35xD61 mm
Weight
Approx. 190g (after packaging)
Enclosure Material
Self extinguishing plastics
ENDA Assistant
💬
Product Selection Assistant

Click here to find the right product for you!

Please choose your preferred language.