EPPC02

Single and 3 Phase Voltage Control, Second Relay Active in Phase Sequence Change, Over-Low Voltage Protection Relay

Compare
EPPC02 Enda Product
Compare
  • Single and three phase protection

  • Phase failure (loss phase) protection

  • Phase sequence protection

  • Adjustable voltage protection

  • Over voltage and/or low voltage protection

  • Contact outputs for system control (OUT, OUT2)

  • Rail mounted, screw-terminal connections

  • CE marked according to European Norms

Manuals

Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C
Protection Degree
IP20, According to EN 60529
Height
Max. 2000m
Outputs
Control Output (OUT)
250V AC, 10A (for resistive load), NO+NC
Control Output (OUT2)
250V AC, 10A (for resistive load), NO+NC
Life Expectancy
Mechanical 10.000.000 operations (under no load), Electrical 50.000 operations (10A at 250V AC, resistive load)
Control Output State
Out LED control output (OUT) lits when device is powered
Out LED control output (OUT) lits when device is powered and phase sequence failed (during this state, OUT2 relay will switch On)

Electrical Characteristics
Supply
125-410V AC +10% -10%
Operating Frequency
45-65 Hz
Power Consumption
Max. 10VA
External Connections
Screw-terminal connections
Reset Time
Max. 0.01s
Housing
Mounting Method
TH35 rail mounting
Dimensions
W18xH84xD62 mm
Weight
Approx. 90g (after packaging)
Enclosure Material
Self extinguishing plastics
Environmental Conditions
Ambient/Storage Temperature
0...+50 ºC / -25...+70 ºC
Relative Humidity
80% relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C
Protection Degree
IP20, According to EN 60529
Height
Max. 2000m
Electrical Characteristics
Supply
125-410V AC +10% -10%
Operating Frequency
45-65 Hz
Power Consumption
Max. 10VA
External Connections
Screw-terminal connections
Reset Time
Max. 0.01s
Outputs
Control Output (OUT)
250V AC, 10A (for resistive load), NO+NC
Control Output (OUT2)
250V AC, 10A (for resistive load), NO+NC
Life Expectancy
Mechanical 10.000.000 operations (under no load), Electrical 50.000 operations (10A at 250V AC, resistive load)
Control Output State
Out LED control output (OUT) lits when device is powered
Out LED control output (OUT) lits when device is powered and phase sequence failed (during this state, OUT2 relay will switch On)

Housing
Mounting Method
TH35 rail mounting
Dimensions
W18xH84xD62 mm
Weight
Approx. 90g (after packaging)
Enclosure Material
Self extinguishing plastics
Please choose your preferred language.